Lufft VENTUS-UMB Ultrasonic Wind Sensor with Heater

Lufft  |  SKU: VENTUS-UMB
$3,01800

Ships in 2-3 Weeks


Need help determining the right product for you? Give our team a call at 609-844-0055.

The accurate wind sensor uses the run-time differential method for determining the wind speed and wind direction. It provides output for instantaneous values, vector and scalar means, the maximum gust of wind and wind direction, the maximum/minimum values and the virtual temperature. Data output through serial or analogue interfaces provides compatibility of the Lufft Ventus for commercially available hydrometeorological dataloggers and PLC systems. An automatic heater ensures reliable operation even in harsh environmental conditions.

Wind speed, wind direction, virtual temperature, barometric pressure

Ultrasonic

Wind detection with birdproof construction, maintenance-free measurement, suitable for extreme ambient conditions, ice-free operation, vibration and seawater resistant, compatible interfaces

SDI-12, RS-485 with supported protocols Binary, ASCII, NMEA, Modbus & analogue output

Highlights:

  • Measuring wind direction and speed insusceptibly to bird nesting thanks to roofed construction
  • Built-in data pre-processing, universal interfaces and selectable output protocols – compatible with OTT-dataloggers, commercially available HydroMet dataloggers and PLS systems
  • Maintenance-free operation – no moving parts that can wear out thanks to ultrasonic measuring method; no need for re-calibration
  • Suitable for all climate zones; also for solar-powered automatic meteorological stations
  • Integrated heater that can be switched on if there is danger of frost – guarantees ice-free operation in extremely low temperatures until -40 °C
  • Vibration and seawater resistant – also applicable in coastal regions
  • Successfully tested and certified in extreme ambient conditions (temperature, air humidity, electromagnetic compatibility, vibration, salt spray, and icing)
  • Embedded algorithms that provides the wind speed and direction as actual and averaged values
  • Wind gust calculation regarding WMO (Guide to Meteorological Instruments and Methods of Observation)

The robust and maintenance-free wind sensor is designed for professional meteorological applications in all climate zones. It delivers reliable data, even in extreme ambient conditions.

Examples of Use:

  • Synoptical automatic weather stations of meteorological services
  • Weather stations at airports, marinas and onboard ships
  • Wind turbine control
  • Weather observation for road and traffic control systems
  • Mountain weather stations for avalanche and flood warning
  • Hydro-meteorological stations
LUFFT VENTUS-UMB 8371.UM
Dimensions Ø approx. 150 mm, height approx. 200mm
Weight approx. 1.7kg
Wind direction
Principle Ultrasonic- 2.4Ghz
Measuring range 0.1…359.9°
Resolution 0.1°
Accuracy ±2° RMSE >1.0m/s
Start-up Threshold 0.1m/s
Wind speed
Principle Ultrasonic- 2.4Ghz
Measuring range 0…75m/s
Resolution 0.1m/s
Accuracy ±0.2m/s or ±2% of reading, whichever is greater
Start-up Threshold 0.1m/s
Unit m/s; km/h; mph; kts
Virtual temperature
Principle Ultrasonic
Measuring range -58...+158°F (-50°C...+70°C)
Resolution 0.1 K
Accuracy ±2.0K (without heater and without sun exposure)
Measuring rate 60 partial measurements/15 full measurements per second
Measurement output rate 1-10 seconds adjustable, default 10s
Air pressure
Principle MEMS Capacitive
Measuring range 300…1200 hPa
Accuracy ±0.5 hPa
Data output digital
Interface RS 485 semi-/full duplex, isolated
Baud rate 1200-57600
Measurement rate instantaneous value 1-10s
Measurement Avg (arithmetic, vector), Min, Max 1-10min
Status Heating, sensor failure
Data output analog
only semi-duplex mode
output signal 4-20mA, 0...10V frequency (instantaneous, avg, min, max)
Load max.300 Ohm
Resolution 16bit
General Information
Operating temperature -40..+60°C (with heating)
Bus operation up to 32 devices
Operating voltage electronics 24 VDC ±10 % or 24 VDC/1.2 VA
with heating 24 VDC, max. 240 VA (140 W + 100 W)
connection 8 pole plug
Housing material Anodized aluminium, seawater-proof
Protection IP 65
Pole diameter 50 mm / 2"
factory certificate yes
Jarring test According to IEC 60945
Corrosion test According to MIL-STD-810 Method 509.3
Ice-free test According to MIL-STD-810F Method 521.2