6263 Vantage Pro2 Plus Wireless Weather Station with WeatherLink Console, 24hr Fan Aspirated Radiation Shield, UV & Solar Sensors
The
6263 Vantage Pro2 Plus weather station provides the technology and real-time data
you need to respond to changing conditions and make timely decisions.
Engineered to handle rugged environments and deliver data with
scientific precision year after year, the economical Vantage Pro2 offers
the professional weather observer, or serious weather enthusiast, a
robust performance with a wide range of options and sensors.
Complete Features:
- Accurate, reliable weather monitoring with real-time data updates every 2.5 seconds
- Outside temperature and humidity sensors in a 24-hour Fan-Aspirated Radiation Shield for maximum accuracy
- Sensor suite also reports wind speed and direction, rainfall, UV and Solar radiation
- Industry-leading transmission range of 1,000’/300 m from the sensor suite to the console
- Mount the anemometer up to 40’/12 m from the rest of the sensor suite for flexible siting
- Sensor suite’s rugged, weather-proof housing gives you years of reliable data
- Includes WeatherLink Console (6313) with a vibrant, HD color touchscreen
- Sensor suite is solar-powered with battery backup; the console is AC-powered with battery backup
WeatherLink Console
The
WeatherLink Console revolutionizes the way you access, analyze, and
understand your hyperlocal weather data reported by your Vantage
Pro2™or Vantage Vue® sensor suite, or your custom network of multiple
Davis sensors. One intuitive device lets you receive and display data
from your local network and connect to Wi-Fi to push your data to the
WeatherLink Cloud.
WeatherLink Features:
- Use the vibrant HD touchscreen to easily navigate, view, and analyze your weather data on one intuitive device
- Customize
the dashboard to show up to 21 parameters – from temperature to the
wind to rain – and see the information that matters to you
- Use the full database of historical records stored right on the console to create custom graphs and analyze your data
- Choose from hundreds of parameters and a dozen sounds to get notified about the environmental changes you care about most
- The
WeatherLink Console is a fully functional and powerful data display,
storage, and analysis tool on its own – no Wi-Fi required. Or you can
connect to Wi-Fi to join the WeatherLink community and upload and share
data safely and securely
24hr Fan Aspirated Radiation Shield:
The
24-Hour Fan Aspirated Radiation Shield includes a solar- and
battery-powered, motor-driven fan that draws a constant airflow through
the sensor chamber. At night, when the effects of radiation are less,
the fan runs on the battery. This provides more accurate temperature
readings than passive shielding alone.
24hr Fan Aspirated Radiation Shield Features:
- A motor-driven fan draws a constant airflow through the sensor chamber at 500 feet per minute (2,5 m/s)
- At
night, when the effects of radiation are less, this solar-powered model
runs on battery power and the airflow slows to 280 feet per minute (1,4
m/s)
- Install your own sensor in the sensor chamber
- Sensor chamber: (inch) 2.24” x 3” / (mm) 56.8 mm x 76.2 mm
- Includes 10 plates, rechargeable batteries, mounting hardware, and 25 ft. (7,6 m) cable
UV Sensor:
Davis
Instruments UV index sensor measures the sunburning portion of the UV
spectrum. It measures global solar UV irradiance: the sum of the
components of solar UV transmitted directly and those scattered in the
atmosphere. It reports the UV index, dose rate, and daily and
accumulative doses of UV light. This sensor is an excellent addition to
the Vantage Pro2 weather station.
UV Sensor Features:
- Measures the sunburning portion of the UV spectrum. Allows you to display UV index, dose rate, and daily and accumulated dose
- Diffuser provides excellent cosine response
- Measures global solar UV irradiance, which includes both directly transmitted and scattered UV
- Transducer responds only to radiation in the region of interest and is stable in the presence of heat and humidity
- Cutoff ring with a comb structure for cosine response of ± 4% FS
- Two-piece
housing minimizes radiation heating, allows convection cooling of the
sensor, and prevents the trapping of water or dust
US Version - Designed for use in the USA